Chosen Solution

I have a white westinghouse refrigerator, I am unable to find the pinout of this connector on the thermostat part. The connector is corroded Ang one of it burned. Maybe someone can help me troubleshoot and find the right wiring for this thing.

It has 4 wires going to the thermostat, but I am unable to locate the wires for the 220v 1 Amp bulb that’s normally on. Update (12/14/2020)

here is the model number Update (12/14/2020) Update. Everything’s working now properly, heat shrink tubes did the job. I was on it for 4-5 hours and finally it’s done. @jayeff thanks for the help. ELECTRIC tapes temporarily for the main connection, I’ll fix the mess tommorow.

. Made a small hole so I can see the tubing properly sealed. Still worried about the water dripping on that foam part.

Hi @echo26 , The wiring diagram as shown on the product label shows the thermostat as having possibly 2 yellow wires on pin 6 (or 1 if there are two yellow wires on the door switch (it is marked as “switch” so I assume it is the door switch so that the light operates when the door is opened). You would need to check the defrost heater harness wire colours if they are blue and white or black and white as B might mean black and BL might be blue If the two defrost heater harness wires are blue and white then the thermostat connections are 2 x Yellow - pin 6, Blue - pin 3, Black and White - pin 4 If the two defrost heater harness wires are black and white then it is 2 x Yellow - pin 6, Black - pin 3, Blue and White - pin 4 The lamp should have a red wire going back to the overload protector near the compressor (or the red wire in the power cord) and a black (or maybe blue) wire going to the door switch. The other wire on the door switch is a yellow wire.